smartctl version 5.32 Copyright (C) 2002-4 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: IC35L020AVER07-0 Serial Number: SVPTVG53395 Firmware Version: ER2OA46A Device is: In smartctl database [for details use: -P show] ATA Version is: 5 ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1 Local Time is: Mon Apr 3 18:14:51 2006 EDT ==> WARNING: IBM Deskstar 60GXP drives may need upgraded SMART firmware. Please see http://www.geocities.com/dtla_update/index.html#rel and http://www-3.ibm.com/pc/support/site.wss/document.do?lndocid=MIGR-42215 SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 725) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 12) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 085 085 060 Pre-fail Always - 269 2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0 3 Spin_Up_Time 0x0007 136 136 024 Pre-fail Always - 107 (Average 113) 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 854 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 100 100 020 Pre-fail Offline - 0 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 711 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 763 192 Power-Off_Retract_Count 0x0032 100 100 050 Old_age Always - 854 193 Load_Cycle_Count 0x0012 100 100 050 Old_age Always - 854 194 Temperature_Celsius 0x0002 189 189 000 Old_age Always - 29 (Lifetime Min/Max 2/56) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 24 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 1769 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 1769 occurred at disk power-on lifetime: 711 hours (29 days + 15 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 59 01 40 00 00 e0 Error: UNC at LBA = 0x00000040 = 64 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c4 00 02 3f 00 00 e0 00 00:02:54.500 READ MULTIPLE c4 00 02 7d 00 00 e0 00 00:02:54.500 READ MULTIPLE c4 00 04 7b 00 00 e0 00 00:02:50.000 READ MULTIPLE c4 00 06 79 00 00 e0 00 00:02:45.500 READ MULTIPLE c4 00 18 67 00 00 e0 00 00:02:41.000 READ MULTIPLE Error 1768 occurred at disk power-on lifetime: 711 hours (29 days + 15 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 59 03 7c 00 00 e0 Error: UNC at LBA = 0x0000007c = 124 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c4 00 04 7b 00 00 e0 00 00:02:50.000 READ MULTIPLE c4 00 06 79 00 00 e0 00 00:02:45.500 READ MULTIPLE c4 00 18 67 00 00 e0 00 00:02:41.000 READ MULTIPLE c4 00 1a 65 00 00 e0 00 00:02:36.500 READ MULTIPLE c4 00 1c 63 00 00 e0 00 00:02:31.900 READ MULTIPLE Error 1767 occurred at disk power-on lifetime: 711 hours (29 days + 15 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 59 03 7c 00 00 e0 Error: UNC at LBA = 0x0000007c = 124 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c4 00 06 79 00 00 e0 00 00:02:45.500 READ MULTIPLE c4 00 18 67 00 00 e0 00 00:02:41.000 READ MULTIPLE c4 00 1a 65 00 00 e0 00 00:02:36.500 READ MULTIPLE c4 00 1c 63 00 00 e0 00 00:02:31.900 READ MULTIPLE c4 00 3e 41 00 00 e0 00 00:02:27.400 READ MULTIPLE Error 1766 occurred at disk power-on lifetime: 711 hours (29 days + 15 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 59 03 7c 00 00 e0 Error: UNC at LBA = 0x0000007c = 124 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c4 00 18 67 00 00 e0 00 00:02:41.000 READ MULTIPLE c4 00 1a 65 00 00 e0 00 00:02:36.500 READ MULTIPLE c4 00 1c 63 00 00 e0 00 00:02:31.900 READ MULTIPLE c4 00 3e 41 00 00 e0 00 00:02:27.400 READ MULTIPLE c4 00 40 3f 00 00 e0 00 00:02:23.000 READ MULTIPLE Error 1765 occurred at disk power-on lifetime: 711 hours (29 days + 15 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 59 1a 65 00 00 e0 Error: UNC at LBA = 0x00000065 = 101 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c4 00 1a 65 00 00 e0 00 00:02:36.500 READ MULTIPLE c4 00 1c 63 00 00 e0 00 00:02:31.900 READ MULTIPLE c4 00 3e 41 00 00 e0 00 00:02:27.400 READ MULTIPLE c4 00 40 3f 00 00 e0 00 00:02:23.000 READ MULTIPLE c4 00 01 00 00 00 e0 00 00:01:00.600 READ MULTIPLE SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short captive Completed: read failure 50% 710 64 # 2 Short captive Completed: read failure 50% 710 64 # 3 Short captive Completed: read failure 60% 710 9549768 # 4 Short captive Completed: read failure 50% 710 64 # 5 Short captive Completed: read failure 50% 710 64 # 6 Short captive Completed: read failure 60% 710 64 # 7 Extended offline Completed: read failure 90% 710 64 # 8 Short captive Completed: read failure 50% 710 64 # 9 Short offline Completed: read failure 60% 707 64 #10 Extended captive Completed: read failure 90% 706 64 #11 Short offline Completed: read failure 60% 703 50754 #12 Extended offline Completed: read failure 90% 702 64 #13 Short offline Completed: read failure 50% 702 64 #14 Extended captive Completed: read failure 90% 702 64 #15 Extended offline Completed: read failure 90% 701 64 #16 Short captive Completed: read failure 50% 701 64 #17 Short captive Completed: read failure 50% 701 64 #18 Short offline Completed: read failure 50% 701 64 #19 Short captive Completed: read failure 50% 700 64 #20 Extended captive Completed: read failure 90% 700 64 #21 Short captive Completed: read failure 50% 700 64 Device does not support Selective Self Tests/Logging